Cisco Cisco 1700 2600 3600 3700 Series VPN Module White Paper

Page of 55
 
 
© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 30 of 55 
local chassis. From the local chassis 
perspective, whichever supervisor boots first will become the “In-chassis 
Active” supervisor, while the second supervisor will be become the “In-chassis Standby” supervisor. See Figure 14 
Figure 14.    Virtual Switching System with Quad-Sup Uplink Forwarding 
 
With the In-chassis Standby supervisor fully booted, the uplink ports are fully operational. They can be used as part 
of the VSL port-channel interfaces or other connectivity, just like ports on any other line card. 
Note:   Quad-Sup Uplink Forwarding is supported on Supervisor720-10G-based systems. Quad-Sup Uplink 
forwarding is not supported with Sup2T based systems. The Sup2T will support VSS-based supervisor redundancy 
in a future software release. 
RPR-WARM Redundancy Mode 
The In-chassis Standby supervisor runs a new redu
ndancy mode called “RPR- Warm,” stated “RPR minus Warm”. 
The RPR- Warm redundancy mode is only available in the Virtual Switching System. 
In addition to fully booting the in-chassis standby supervisor and providing fully operational uplink ports, the RPR- 
Warm redundancy mode also provides synchronization of the necessary information to allow the In-chassis 
Standby supervisor to reload and take over as the in-chassis active supervisor if needed. The RPR- Warm 
redundancy mode synchronizes the following crucial variables and data structures: 
● 
Startup-config 
● 
Vlan.dat 
● 
BOOT ROMMON variable 
● 
CONFIG_FILE ROMMON variable 
● 
BOOTLDR ROMMON variable 
● 
DIAG ROMMON variable 
● 
SWITCH_NUMBER ROMMON variable 
It is important to note that the RPR- Warm redundancy mode is not a stateful redundancy mode, as it applies to the 
local chassis. In other words, if the in-chassis active supervisor fails, the In-chassis standby supervisor will detect 
the failure and reload the local chassis. Subsequently, the former in-chassis standby supervisor will boot as the in-
chassis active supervisor.