Cisco Cisco 1700 2600 3600 3700 Series VPN Module White Paper

Page of 55
 
 
© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 33 of 55 
Figure 17.   
Abbreviated Output From the “show switch virtual redundancy” CLI with Quad-Sup Uplink Forwarding Enabled 
 
Configuration Synchronization 
When the redundancy-framework progression between the active supervisor engine and standby supervisor 
engine is reached, the configuration is synchronized between active virtual switch and standby virtual switch. 
The configuration file contains the configuration for the entire Cisco Virtual Switching System, and overwrites the 
configuration that exists on the standby virtual switch. Both the bulk configuration synchronization and the 
incremental configuration synchronization are sent through internal control messages across the VSL. As a result, 
the configuration in the standby virtual switch NVRAM is overwritten. 
Virtual Switch Priorities and Switch Preemption 
Because the Cisco Virtual Switching System consists of two chassis merged into a single entity, you can designate 
a particular physical switch to prefer an active role, while its peer prefers the standby role. This designation is 
usually determined by the following by default: 
If switches are initiated at different times, then the switch that is initiated first becomes the active virtual switch. 
If the switches are initiated simultaneously, the switch with the lower switch ID becomes the active virtual switch. 
You can alter the default behavior by using the Virtual Switch Priorities feature and the Switch Preemption function. 
Virtual Switch Priorities 
Virtual Switch Priorities are assigned to each member of the Cisco Virtual Switching System under the Virtual 
Switch Configuration mode. By influencing the weighting of the priorities of each switch, you can deterministically 
define which physical switch will prefer the active virtual switch role or the standby virtual switch role. 
A sample configuration follows: 
vss#conf t  
Enter configuration commands, one per line. End with CNTL/Z.  
vss(config)#switch virtual domain 10