Operating using ICIM LCD, Continued 
Sub-Menu 1 -- Optical Information 
The illustration below shows sub-menu 1 of the OptoStar II forward receiver 
module - Optical Information.   
 
The default lower limit of the optical input power alarm threshold is -4. 0 dBm; 
and upper limit is 4.0 dBm. The cursor stays in the “Low” box by default. Also, 
this sub-menu provides specific value of optical input power.   
• 
To configure the lower limit of the optical alarm threshold (minimum output 
power is no less than (standard value - 4. 0) dBm).   
1.  Press SET button to start the configuration; 
2.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
3.  Press ► button to move the cursor to “Set”; 
4.  Press SET button to save the configuration. 
• 
To configure the upper limit of the optical alarm threshold (maximum output 
power is no more than (standard value + 4. 0) dBm).   
1.  Press ▼ button to leave the cursor in the “High” box; 
2.  Press SET button to start the configuration; 
3.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
4.  Press ► button to move the cursor to “Set”; 
5.  Press SET button to save the configuration. 
 
 