Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 137
78-748704-01 Rev C 
Installation 
2-15 
Connect Multiple Chassis 
Introduction 
The Prisma II platform allows an ICIM to be located in one chassis to control 
application modules located in several other chassis.  This communication “daisy-
chain” can be enabled by connecting cables to the ICIM IN and ICIM OUT 
connectors located on the connector interface panel of the chassis.   
Note:  An ICIM can control a maximum of 82 modules.  Depending on your 
application, this is typically six or seven chassis to a rack.  Do not exceed these limits.   
Cabling Requirements 
The cable required for both ICIM IN and ICIM OUT connections is a standard “off 
the shelf” serial extension cable, DB-9 female to DB-9 male, with connectors that are 
a serial 9-pin D-shell (EIA 574/232). 
This cable can be purchased at your local computer store or from Cisco.  The Cisco 
part number for a 6-foot serial extension cable is 180143.   
Connecting the Chassis 
Follow these steps to make chassis-to-chassis ICIM IN and ICIM OUT connections. 
 
1. 
Connect the serial extension cable from the ICIM OUT of the chassis 
containing the ICIM to the ICIM IN connector of the second chassis. 
2. 
Connect a serial extension cable from the ICIM OUT of the second chassis to 
the ICIM IN of the third chassis. 
3. 
Continue this “daisy-chain” connection until all desired chassis are 
connected.   
Notes:   
• 
All chassis connected in the daisy-chain must be powered and have a fan tray 
installed.  A chassis that is connected but is either not powered or does not have a 
fan tray installed will cause faulty operation of the ICIM.   
• 
All chassis connected in the daisy-chain must have a unique chassis ID number. 
Additional Information 
For more information on chassis-to-chassis communications, including connections 
for TNCS and external alarm connections, see Communication Connections in 
Chapter 2 of the Prisma II Chassis Installation and Operation Guidepart number 
713375