Prisma II Redundancy Interface Panel Overview 
Introduction 
The Prisma II Redundancy Interface Panel is an accessory to the Prisma II platform.  
The interface panel is intended to be used with the master/slave feature and the 
contact closure alarm feature of the Prisma II platform. 
The terminals on the interface panel serve as extensions to the two DB-37 connectors 
labeled ALARM IN and ALARM OUT on the connector interface panel of the 
chassis.   
The interface panel consists of the rack-mount panel, two cables, and jumper wire.  
The panel is to be mounted near the designated chassis in a 19-inch rack. 
Slave Mode Operation in Prisma II Modules  
All Prisma II modules can be hard-wired to operate as a backup or slave module in a 
parallel redundant mode.   
In this mode, a master and a slave module are interconnected and configured so that, 
if a critical fault occurs in the master, its output is turned off.  When this happens, 
the slave module senses that the master is no longer operating and is automatically 
enabled.  If the master's critical alarm disappears (for example, by replacing the 
module), the slave turns off and the master is re-enabled. 
Prisma II modules are factory configured in master mode.  To operate in slave mode, 
modules must be hard-wire connected and manually reconfigured using an ICIM, 
LCI software, or TNCS software. 
Redundancy Interface Panel Illustration (Front) 
The front of the interface panel is shown below. 
 
Redundancy Interface Panel Illustration (Rear) 
The rear of the interface panel is shown below.