Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 137
3-18 
Operation Using the ICIM 
78-748704-01 Rev C 
Monitor Processor Status Using the ICIM 
Introduction 
The ICIM allows you to monitor the operating status of parameters. 
STATUS Parameters 
The table below describes the monitored status parameters for this processor. 
 
Parameter  
Units 
Function 
ExtPower 
OK or Fault 
Indicates DC power supply voltage status. 
+1_8VInt 
Internal voltage level-nominal 1.8 V DC. 
+3_3VInt 
Internal voltage level-nominal 3.3 V DC. 
ProcTemp 
°
Indicates processor temperature. 
Rcv1Pres 
Yes or No 
Indicates if receiver 1 is installed. 
Rcv1Type 
1 or 2 
Indicates what type receiver is installed. 
1 = standard range receiver - PIN 
2 = extended range receiver - APD 
RF_Out1A 
RF_Out1B 
On or Off 
Indicates whether the actual output of RF 
channels A and B are On or Off. 
Rcv2Pres 
Yes or No 
Indicates if receiver 2 is installed. 
Rcv2Type 
1 or 2 
Indicates what type receiver is installed. 
1 = standard range receiver - PIN 
2 = extended range receiver - APD 
RF_Out2A 
RF_Out2B 
On or Off 
Indicates whether the actual output of RF 
channels A and B are On or Off. 
Recv1 
Active or Idle  Indicates if receiver 1 is active.  
RednRcv1 
Master, 
Internal, or 
External 
Indicates if receiver 1 has been configured as 
MasterInternal, or External