Ethernet Media Converters
Industrial Gigabit Ethernet to fiber media converter
The IMC-101G industrial Gigabit media converters are designed to 
provide reliable and stable 10/100/1000BaseT(X) to 1000BaseSX/
LX/LHX/ZX media conversion in harsh industrial environments. The 
IMC-101G’s industrial design is excellent for keeping your industrial 
automation applications running continuously, and each IMC-101G 
10/100/1000BaseT(X) and 1000BaseSX/LX/LHX/ZX supported
 
Link Fault Pass-Through (LFP)
 
Power failure, port break alarm by relay output
 
Redundant power input
 
-40 to 75°C operating temperature range (T models)
 
Designed for hazardous locations
 
converter comes with a relay output warning alarm to help prevent 
damage and loss. All IMC-101G models are subjected to a 100% 
burn-in test, and are available in models that support a standard 
operating temperature range of 0 to 60°C, and an extended operating 
temperature range of  -40 to 75°C.
Technology
Standards: 
IEEE 802.3 for 10BaseT 
IEEE 802.3u for 100BaseT(X) and 100BaseFX 
IEEE 802.3ab for 1000BaseT(X) 
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
Interface
RJ45 Ports: 10/100BaseT(X)
Fiber Ports: 100BaseFX (SC/ST connectors)
LED Indicators: PWR1, PWR2, FAULT, 10/100M (TP port), 1000M 
(TP and Fiber port)
DIP Switches: Port break alarm mask, Fault Pass-Through, Fiber AN/
Force
Alarm Contact: One relay output with current carrying capacity of 1 A 
@ 24 VDC
Optical Fiber
Multi-mode Transmission Distance: 
1000BaseSX: 
• 0 to 500 m, 850 nm (50/125 µm, 400 MHz*km) 
• 0 to 275 m, 850 nm (62.5/125 µm, 200 MHz*km) 
1000BaseLX: 
• 0 to 1100 m, 1310 nm (50/125 µm, 800 MHz*km) 
• 0 to 550 m, 1310 nm (62.5/125 µm, 500 MHz*km)
Single-mode Transmission Distance: 
1000BaseLX: 0 to 10 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))  
1000BaseLHX: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))  
1000BaseZX: 0 to 80 km, 1550 nm (9/125 µm, 19 PS/(nm*km))
Physical Characteristics
Housing: Metal, IP30 protection
Dimensions: 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight: 630 g
Installation: DIN-Rail mounting, wall mounting (with optional kit)
Environmental Limits
Operating Temperature: 
Standard Models: 0 to 60°C (32 to 140°F) 
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
Power Requirements
Input Voltage: 24 VDC (12 to 45 VDC), redundant inputs
Input Current: 0.11 A (@ 24 V)
Connection: Removable terminal block
Overload Current Protection: 1.1A
Reverse Polarity Protection: Present
Regulatory Approvals
Safety: UL508
EMI: FCC Part 15, CISPR (EN55022) class A
EMS: 
EN61000-4-2 (ESD), level 3 
EN61000-4-3 (RS), level 3 
EN61000-4-4 (EFT), level 3 
EN61000-4-5 (Surge), level 2 
EN61000-4-6 (CS), level 3 
EN61000-4-8 
EN61000-4-11
Hazardous Location:       
UL/cUL Class1, Division 2, Groups A, B, C, and D,   ATEX Class1, 
Zone 2, Ex nC IIC
Freefall: IEC60068-2-32
Shock: IEC60068-2-27
Vibration: IEC60068-2-6
MTBF: 500,000 hrs; Database: Telcordia (Bellcore), GB