Moxa EDS-308-S-SC-80-T User Manual

Page of 3
1
w w w. m o x a . c o m
i n f o @ m o x a . c o m
Industrial Ethernet Solutions
5, 8, 9, and 16-port unmanaged Ethernet switches
EDS-305/308/309/316 Series
Introduction
The EDS-305/308/309/316 are 5, 8, 9, and 16-port Ethernet switches 
that provide an economical solution for your industrial Ethernet 
connections. The built-in relay warning function alerts network 
engineers when power failures or port breaks occur, and the switches 
are designed for harsh industrial environments, such as in hazardous 
locations (Class I, Div. 2/ATEX). The switches comply with FCC, UL, 
Redundant dual 24 VDC power inputs
 
Relay output warning for power failure and port break alarm
 
Broadcast storm protection
 
Transparent transmission of VLAN tagged packets
 
-40 to 75°C operating temperature range (T models)
 
Specifications
and CE standards, and come in two model types: standard operating 
temperature range models (0 to 60°C) and wide operating temperature 
range models (-40 to 75°C). Both models undergo a 100% burn-in 
test to ensure that they fulfill the special needs of industrial automation 
control applications. The EDS-305/308/309/316 switches can be 
installed easily on a DIN-Rail or in a distribution box.
Technology
Standards: 
IEEE 802.3 for 10BaseT 
IEEE 802.3u for 100BaseT(X) and 100BaseFX 
IEEE 802.3x for Flow Control
Processing Type: Store and Forward
Flow Control: IEEE 802.3x flow control, back pressure flow control
Switch Properties
MAC Table Size: 1 K (EDS-305/308/309), 4 K (EDS-316)
Packet Buffer Size: n/a (EDS-305), 512 Kbit (EDS-308/309), 1.5 Mbit 
(EDS-316)
Interface 
Fiber Ports: 100BaseFX ports (SC/ST connector)
RJ45 Ports: 10/100BaseT(X) auto negotiation speed, Full/Half duplex 
mode, and auto MDI/MDI-X connection
DIP Switches: Port break alarm mask
LED Indicators: PWR1, PWR2, FAULT, 10/100M (TP port), 100M 
(fiber port)
Alarm Contact: 1 relay output with current carrying capacity of 1 A @ 
24 VDC 
Optical Fiber
    
100BaseFX
Multi-mode
Single-mode
Single-mode, 
80 km
Wavelength
1300 nm
1310 nm
1550 nm
Max. TX
-10 dBm
0 dBm
0 dBm
Min. TX
-20 dBm
-5 dBm
-5 dBm
RX Sensitivity
-32 dBm
-34 dBm
-34 dBm
Link Budget
12 dB
29 dB
29 dB
Typical Distance
5 km, 2 km 
(EDS-316-T)a
40 km c
80 km d
4 km, 2 km 
(EDS-316-T)b
Saturation
-6 dBm
-3 dBm
-3 dBm
a. 50/125 μm, 800 MHz*km fiber optic cable 
b. 62.5/125 μm, 500 MHz*km fiber optic cable 
c. 9/125 μm single-mode fiber optic cable
d. 9/125 μm single-mode fiber optic cable (80 km)
Power Requirements
Input Voltage: 
EDS-305/308: 24 VDC (12 to 48 VDC), redundant dual inputs 
EDS-309/316: 24 VDC (12 to 45 VDC), redundant dual inputs