Thermal Specifications
Notes:
1.
These values are specified at V
CC_MAX
 for all processor frequencies. Systems must be designed to ensure 
the processor is not to be subjected to any static V
CC
 and I
CC
 combination wherein V
CC
 exceeds V
CC_MAX
 at 
specified ICC. Please refer to the electrical loadline specifications in 
2.
Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the 
maximum power that the processor can dissipate. TDP is measured at maximum T
CASE
.
3.
Power specifications are defined at all VIDs found in 
. Processors may be delivered under multiple 
VIDs for each frequency.
4.
FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor 
frequency requirements.
Notes:
1.
Thermal Profile A (refer to 
) is representative of a volumetrically unconstrained platform. Thermal 
Profile B (refer to 
) is representative of a volumetrically constrained platform.
2.
Implementation of Thermal Profile A should result in virtually no TCC activation. Utilization of thermal 
solutions that do not meet Thermal Profile A will result in increased probability of TCC activation and may 
incur measurable performance loss.
3.
Refer to the Intel® Xeon® Processor 5500/5600 Series Thermal/Mechanical Design Guide for system and 
environmental implementation details.
Table 7-4.
Advanced Server/Workstation Platform Thermal Specifications
Core
Frequency
Thermal Design 
Power (W)
Minimum
T
CASE
 (°C)
Maximum
T
CASE
 (°C)
Notes
Launch to FMB
95
5
1, 2, 3, 4
Figure 7-3. Advanced Server/Workstation Platform Thermal Profile A and B (6 Core)
40
45
50
55
60
65
70
75
80
85
0
5
10
15
2 0
25
30
35
40
45
50
55
60
65
70
75
8 0
85
90
95
Po we r [W]
T
e
m
p
er
at
u
re
 [
C
]
Thermal Profile  B
Y  = 0.257 *  x + 56.9
Thermal Profile A
Y  = 0.180 *  x + 56.9
TCASE_MAX is a thermal solution  design  point. 
In actuality, units will not significantly exceed 
TCASE_MAX_A due  to TCC activation.
40
45
50
55
60
65
70
75
80
85
0
5
10
15
2 0
25
30
35
40
45
50
55
60
65
70
75
8 0
85
90
95
Po we r [W]
T
e
m
p
er
at
u
re
 [
C
]
Thermal Profile  B
Y  = 0.257 *  x + 56.9
Thermal Profile A
Y  = 0.180 *  x + 56.9
TCASE_MAX is a thermal solution  design  point. 
In actuality, units will not significantly exceed 
TCASE_MAX_A due  to TCC activation.