4. Connect flexible metal appliance connector to the adapter on the range. Position 
range to permit connection at the shut-off valve.
5. When all connections have been made, make sure all range controls are in the 
off position and turn on the main gas supply valve. Use a liquid leak detector at 
all joints and connections to check for leaks in the system.
WARNING
To prevent death, personal injury, explosion, and/or fire hazard, DO NOT use a 
flame to check for gas leaks.
When using test pressures greater than ½ psig to pressure-test the gas supply 
system of the residence, disconnect the range and individual shut-off valve from 
the gas supply piping. When using test pressures of ½ psig or less to test the gas 
supply system, simply isolate the range from the gas supply system by closing the 
individual shut-off valve.
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Adapter
Flex 
Connector 
(6-ft max.)
Adapter
Gas Shut-Off Valve
0.5-in or 0.75-in 
Gas Pipe
Tubing Line to 
Oven Burner 
Control Valve
Gas Flo
w int
o R
ange
Pressure 
Regulator
Tubing Line 
to Cooktop 
Control 
Manifold
NOTE
If your area requires a rigid pipe hookup, 
contact a qualified installer, service agency, 
or gas supplier.
NOTE
The gas shut-off valve should be installed 
in an accessible location in the gas piping, 
external to the appliance, for the purpose 
of turning on or shutting off the gas to the 
appliance.
Step 3. Convert to lp gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas. Any 
Samsung gas range can be converted to use LP gas. Refer to page 55 in the User 
Manual to contact a qualified service technician.
The conversion process should only be performed by a qualified LP gas installer. 
Conversion instructions and LP orifices will be supplied with the LP conversion kit. 
The conversion to LP requires all burner orifices to be changed (5 surface burners 
and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All 
replaced orifices must be left with the consumer, including the instructions and 
retrofit sizes and orifice indication. 
Checking the flame quality all burner after converting to lp gas.
BURNER ORIFICE SIZES AND OUTPUT 
RATINGS (LP Gas [Propane] 10 in WCP)
BURNER ORIFICE SIZES AND OUTPUT 
RATINGS (Natural Gas 5 in WCP)
Burner 
Location
BTU 
Rate
Orifice Size 
[mm]
Burner 
location
BTU 
Rate
Orifice size [mm]
RF
16,500
In: 0.46/
Out: 0.83 (2 pcs)
RF
22,000
In: 0.85/
Out: 1.36 (2 pcs)
LF
11,500
1.04
LF
15,000
1.78
RR
4,000
0.62
RR
5,000
1.01
LR
7,500
0.83
LR
9,500
1.40
CTR
7,500
0.83
CTR
9,500
1.38
BAKE
15,000
1.15
BAKE
18,000
1.90
BROIL
14,500
1.12
BROIL
13,500
1.64