• Make sure to drill only one
hole after choosing the
direction of the pipe.
Fixing the installation plate
The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air
conditioner.
Optional accessories
Tools required for installation
Insulated
Assembly Pipe,
Ø6.35 mm (1)
Insulated Assembly
Pipe, Ø9.52 mm (1)
10/13
Insulated Assembly Pipe,
Ø12.70 mm (1)
18
Insulated Assembly Pipe,
Ø15.88 mm (1)
24
PE T3 Foam Tube
Insulation (1)
Vinyl Tapes (2)
Pipe Clamps A (3) Pipe Clamps B (3)
Cement Nails (6)
M4 x 25 Tapped
Screws (6)
Drain Hose,
length 2m (1)
Putty 100g (1)
•
.x
o
b
y
r
o
s
s
e
c
c
a
e
h
t
n
i
e
b
ll
i
w
y
e
h
t
,
d
e
il
p
p
u
s
e
r
a
s
e
ir
o
s
s
e
c
c
a
e
s
e
h
t
fI
General Tools
• Vacuum Pump(Backward
prevention)
Manifold Gauge
Stud Finder
• Torque Wrench
Pipe Cutter
Reamer
Pipe Bender
Spirit Level
• Screw Driver
Spanner
Drill
L Wrench
•
•
•
•
•
•
•
•
•
•
•
•
•
Measuring Tape
Tools for test operations
•
•
•
Thermometer
Resistance Meter
Electroscope
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
When facing the wall, the pipe and cable can be connected from the:
•
•
•
•
•
•
•
Right (A)
Left (B)
Left (B)
Underside_right (C)
Rear_right or left (D)
B
A
D
C
D
Direction of pipe
1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter
of 65 mm so that it slants slightly downwards.
If using a multi system, refer to the manual supplied with the outdoor unit.
120
27
68
27
(Unit : mm)
Pipe hole
(Ø65 mm)
10/13
170
27
85
27
(Unit : mm)
Pipe hole
(Ø65 mm)
18/24