Sierra Wireless airprime wismo218 User Manual

Page of 110
 
 
 
 
 
WA_DEV_W218_PTS_002 
Rev 005 
Page 85 of 109 
Product Technical Specification & 
Customer Design Guidelines 
Table 40.  Equipment Reference List 
Device 
Manufacturer 
Reference 
Notes 
Communication Tester 
Rhode & Schwartz 
CMU 200 
Quad Band 
GSM/DCS/GPRS 
Current measuring 
power supply 
Agilent 
66321B 
Used for VBATT (for WMP alone) 
Stand alone power 
supply 
Metrix 
AX502 
Used for VBAT (for boards peripherals) 
WISMO218 Development Kit 
The WISMO218 Development Kit is used as a basis for the WISMO218 measurement via an adaptor 
board. The WISMO218 Development Kit can be used to perform consumption measurement using 
several settings. For the list and corresponding description of the settings, see document [3] 
WISMO218 Development Kit User Guide 
and document [1] WISMO218 Hardware Presentation. 
Note: The WISMO218 Development Kit can be replaced by Development Kit WMP100 once a suitable 
socket-up board is available. 
The WISMO218 is only powered by VBATT. The WISMO218 Development Kit board is powered by 
the standalone power supply at VBAT. It is for this reason that the link between VBATT and VBAT 
(J605) must be opened (by removing the solder at the top of the board in the SUPPLY area). Note the 
following information regarding both power supplies. 
 
VBATT is powered by the current measuring power supply (66321B) 
 
VBAT is powered by the standalone power supply (AX502) through TP602 
Also take note of the following additional configuration/settings: 
 
The R600 resistor and the D603 and D604 diodes (around the BAT-TEMP connector) must be 
removed. 
 
The UART2 link is not used; therefore, J201, J202, J203, J204 must be opened (by removing the 
solder).  
 
The “FLASH-LED” must be not used, so J602 must be opened (by removing the solder).  
 
The USB link is not used, therefore J301, J302, J303, J304, J305 must be opened (by removing 
the solder). 
 
The audio is not used, therefore J702, J703, J704, J705, J605 must be opened (by removing the 
solder). 
 
There  is  no  SIM  detect  feature  on  the  WISMO218;  therefore,  J403  must  be  opened  (by 
removing the soldered). 
 
Charging is not used; therefore, R602 must be removed. 
 
C600 and R607 must be removed to avoid unexpected current consumption. 
 
The switch, BOOT (around the “CONFIG” area), must be set to the OFF position. 
The goal of the settings listed above is to eliminate all bias current from VBATT and to supply the 
entire board (except theWISMO218) using VBAT only.