Apple quadra 800.ws 80 Service Manual

Page of 81
 
 Troubleshooting
Symptom Charts - 3
 
System
 
Does not power on; 
screen is black, fan is 
not running, and LED 
is not lit
1 Check power cables.
2 Plug monitor directly into wall socket, and verify that 
monitor has power.
3 Replace power cord.
4 Replace power supply.
5 Replace logic board.  Retain customer’s SIMMs.
Clicking, chirping, 
or thumping
1 Replace power supply.
2 Replace logic board.  Retain customer’s SIMMs.
3 Replace floppy drive cable.