Apple quadra 800.ws 80 Service Manual
Troubleshooting
Symptom Charts - 3
System
Does not power on;
screen is black, fan is
not running, and LED
is not lit
1 Check power cables.
2 Plug monitor directly into wall socket, and verify that
monitor has power.
3 Replace power cord.
4 Replace power supply.
5 Replace logic board. Retain customer’s SIMMs.
Clicking, chirping,
or thumping
1 Replace power supply.
2 Replace logic board. Retain customer’s SIMMs.
3 Replace floppy drive cable.
4 Replace floppy drive.