Access virus os4 User Manual
ACCESS VIRUS OS4
255
System Exclusive Data
value 95. (10: device ID omni; 70:
page A, 05: part 6; 28: parameter
Cutoff, 5F: decimal value 95)
page A, 05: part 6; 28: parameter
Cutoff, 5F: decimal value 95)
Single Dump
[message]=
10
10
Single Dump
bb
Bank Number
00
Single Edit buffer
01..04: Single Bank A..D
01..04: Single Bank A..D
ss
Program Number
0..127 [256 single bytes]
0..127 [256 single bytes]
cs
Checksum
optional
optional
{F0,00,20,33,01,dd,10,bb,ss,[256
single bytes],cs,F7}
single bytes],cs,F7}
When bank number is set to 00,
the program number is the part
number that addresses one of the
sixteen Single Edit buffer in Multi
Mode (00..0F) or the Single buffer
in Single Mode (40).
number that addresses one of the
sixteen Single Edit buffer in Multi
Mode (00..0F) or the Single buffer
in Single Mode (40).
[256 single bytes] contains the Sin-
gle parameter pages A and B, each
128 bytes long.
gle parameter pages A and B, each
128 bytes long.
Checksum is the sum (DeviceID +
10 + BankNumber + ProgramNum-
ber + [256 single bytes]) AND 7F. A
dump with a wrong checksum will
be received, but an error message
will appear on the display.
10 + BankNumber + ProgramNum-
ber + [256 single bytes]) AND 7F. A
dump with a wrong checksum will
be received, but an error message
will appear on the display.
Multi Dump
[message]=
11
11
Multi Dump
bb
Bank Number
00
00
Multi Edit buffer;
01
multi bank
mm
Program Number
0..127 [256 multi bytes]
0..127 [256 multi bytes]
cs
Checksum
optional
optional
{F0,00,20,33,01,dd,11,bb,mm,[256
multi bytes],cs,F7}
multi bytes],cs,F7}
When bank number 00, the
dump destination is the Multi Edit
buffer. In this case the program
number is ignored.
buffer. In this case the program
number is ignored.