ACR Electronics ffmc User Manual

Page of 26
Y1-03-0199 Rev. C 
 
10 
3. 
ZIF Connection and Data Transfer Cable Installation
 
Data is stored in the memory capsule using the data transfer cable which connects to the junction box on the 
bracket,  runs  thru  the  cutter  mechanism  and  attaches  to  the  left  side  of  the  memory  capsule.  This  cable  is 
connected to both the junction box and the memory capsule using ZIF (Zero Insertion Force) connectors. 
NOTE:  ZIF  connectors  are  fragile.  To  avoid  breaking  the  connectors,  touch  them  carefully.  Do  not 
apply too much pressure to the movable part of the connector when opening or closing it.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
To connect the data transfer cable to a ZIF connector, follow these steps:  
 
1.  Using your thumb and index finder, pull down on the movable part of the ZIF connector open.  
2.  Orient the end of the cable with the ZIF connector, and insert the  blank side (or printed side) of the cable into 
the connector.   
3.  While holding the cable firmly in place, close the ZIF connector. To ensure a firm connection, make sure the 
ZIF connector is completely closed. 
 
To disconnect the data transfer cable from a ZIF connector, follow these steps:  
 
1.  Using your thumb and index finder, pull down on the movable part of the ZIF connector open.  
2.  Pull up gently on the movable part of the connector until the cable is released.  
3.  Grasp the cable and pull it out of the connector.  
 
4. 
Data Transfer Cable Window Installation
 
 
After the flex data cable is connected to bracket and memory capsule, the protective window must be installed. 
The  protective  window  caps  come  with  pre-lubricated  O-ring  assembled  on  the  window  cap  ensures  a  tight, 
waterproof fit. 
 
 
Step 1 
Step 2 
Step 3  
 
 
ZIF Connection Install 
Figure 7 
TOP 
BOTTOM