This  message  appears  if  Self-Test  has  passed,  but  the  battery  is  low.  Take 
the beacon to an authorized Service Center for a battery replacement. 
 
NOTES regarding Self-Test logic: 
1.)  When  one  of  the  tests  fail,  the  system  bypasses  the  remaining  tests 
and goes to SELF-TEST FAIL 
 
2.)  The  only  exception  to  #1  is  that  if  the  battery  fails,  the  other  tests  are 
still  performed.  The  system  will  tell  the  user  if  there  are  other  system 
failures by flashing SELF-TEST FAIL. If there are no failures other than 
battery life, the system flashes SELF-TEST PASS, then BATT LOW. 
BATT 