1-3
In-Band Connections
Prior to accessing the Management Module via a network connection, you must first
configure it with a valid IP address, subnet mask, and default gateway using an
out-of-band connection or the BOOTP protocol.
configure it with a valid IP address, subnet mask, and default gateway using an
out-of-band connection or the BOOTP protocol.
Note:
By default BOOTP is disabled and the IP address is set to 192.168.10.1. To
enable BOOTP, see “IP Configuration” on page 2-11.
enable BOOTP, see “IP Configuration” on page 2-11.
After configuring the switch’s IP parameters, you can access the on-board
configuration program from anywhere within the attached network. The on-board
configuration program can be accessed using Telnet from any computer attached to
the network. The switch and stack can also be managed by any computer using a
Web browser (Internet Explorer 4.0, or Netscape Navigator 4.0 or above), or from a
network computer using network management software.
configuration program from anywhere within the attached network. The on-board
configuration program can be accessed using Telnet from any computer attached to
the network. The switch and stack can also be managed by any computer using a
Web browser (Internet Explorer 4.0, or Netscape Navigator 4.0 or above), or from a
network computer using network management software.
Notes:
1. Use the Network Configuration menu to specify the maximum number of
simultaneous Telnet sessions that are supported by the system (up to four).
2. The on-board program only provides access to basic configuration functions.
To access the full range of SNMP management functions, you must use
SNMP-based network management software.
SNMP-based network management software.