Alcatel-Lucent ap70 User Manual

Page of 60
Port Specifications
33
Appendix A
DB-9 Specification
The DB-9 connector attaches to the serial port of a console terminal. 
Communication settings for the port are specified in 
Table A-1
:
“To AP” Specifications
The RJ-45 connector labeled “To AP” attaches to the OmniAccess OAW-AP70 
FE port either directly (if the AP is physically available) or indirectly (if the AP is 
already deployed).
When connecting indirectly, use a straight-through FE coupler to attach the “To 
AP” connector to the FE cable leading directly to the AP’s FE port with no 
intervening hubs, routers, or other network equipment. The cable must be 
8-conductor, Category 5 UTP, straight-through FE cable with a maximum 
length of 100 meters (325 feet).
The OmniAccess OAW-AP70 and serial breakout adapter are plenum rated. 
When is installed in an air-handling space, as described in NEC (2002) Article 
300.22(C), any connecting FE cable should be suitable under NEC Article 
800.50 and marked accordingly for use in plenums and air-handling spaces 
with regard to smoke propagation, such as CL2-P, CL3-P, MPP or CMP.
Install cables in accordance with all applicable local regulations and practices.
“To Network” Specifications
The RJ-45 connector labeled “To Network” attaches to an FE LAN segment. 
This connection is optional unless IEEE 802.11af Power Over Ethernet (POE) is 
used to power the AP during manual provisioning.
A straight-through FE coupler may be used to attach the “To Network” 
connector to a LAN FE cable. The appropriate cable depends on the level of 
connectivity required of the FE port:
z
If the connecting device supports IEEE 802.3af Power Over Ethernet (POE), 
use a 4- or 8-conductor, Category 5 UTP, straight-through FE cable with 
male RJ-45 connectors.
The Alcatel 6000 (with Line Card OAW-LC-2G24FP), the Alcatel 2400, and the 
Alcatel 800 support SPOE.
T
ABLE
A-1 Console Terminal Settings
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control
9600
8
None
1
None