Alcatel-Lucent omni 6600 User Manual

Page of 144
Configuring Power over Ethernet Parameters
Installing and Managing Power over Ethernet (PoE)
page 3-8
OmniSwitch 6600 Family Hardware Users Guide
September 2006
Setting the Capacitor Detection Method
By default, the PowerDsine capacitor detection method is disabled on the OmniSwitch 6600-P24. To 
enable it use the 
lanpower capacitor-detection
 command by entering lanpower capacitor-detection 
followed by the slot number of the OmniSwitch 6600-P24 and enable.
For example, to enable the capacitor detection method on the OS6600-P24 with slot number 2 enter:
-> lanpower capacitor-detection 2 enable
To disable it use the 
lanpower capacitor-detection
 command by entering lanpower capacitor-detection 
followed by the slot number of the OS6600-P24 and disable.
For example, to disable the capacitor detection method on the OS6600-P24 with slot number 2 enter:
-> lanpower capacitor-detection 2 disable
Note. The capacitive detection method should only be enabled support legacy IP phones only—this feature 
is not compatible with IEEE specification 802.3af. Please contact your Alcatel sales engineer or Customer 
Support representative to find out which Alcatel IP phones models need capacitive detection enabled.