Alcatel-Lucent omni 6600 User Manual

Page of 144
OmniSwitch 6600 Family Chassis and Hardware Components
Backup Power Supply
OmniSwitch 6600 Family Hardware Users Guide
September 2006
page 2-29
Power Supply Redundancy
After a backup power supply is installed, the primary (factory-installed) power supply continues to take on 
the full power load for switch operations. Meanwhile, the backup power supply operates in active standby 
mode. If the primary power supply fails unexpectedly, the backup power supply automatically takes up the 
full power load without disrupting the switch.
OS6602-BPS Backup Power Supply Specifications
Input Voltage
85 to 150 VAC
Input Frequency
47 to 63 Hz
Efficiency
75% measured at 115 VAC
Temperature
Operating: 0 to +50 Celsius
Non-Operating: - 40 to +85 Celsius
Relative Humidity
5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)
Altitude
10,000 feet @ +32 Celsius
OS6602-BPS-DC Backup Power Supply Specifications
Input Voltage
36 to 72 VAC
Input Frequency
N/A
Efficiency
75% measured at 115 VAC
Temperature
Operating: 0 to +50 Celsius
Non-Operating: - 20 to +85 Celsius
Relative Humidity
5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)
Altitude
10,000 feet @ +32 Celsius
OS6600-BPS-P PoE Backup Power Supply Specifications
Width
15.50 inches, approx.
Height
2.61 inches, approx.
Height (rack units)
1.5 RU
Depth
4.53 inches, approx.
Ambient Temperature 
0 to +70 deg C, operating; 
-40 to +85 deg C, non-operating
Humidity
5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)
Altitude
10000 feet at +32 deg C, operating; 50000 feet, non-operating