OmniSwitch 6600 Family Chassis and Hardware Components
Backup Power Supply
OmniSwitch 6600 Family Hardware Users Guide
September 2006
page 2-35
Viewing Power Supply Status for Stacked Configurations
When entering the show power command on the primary switch in a stacked configuration, you can either 
enter only the show power syntax or you can specify a specific slot number. For more information, refer 
to the examples below:
A Slot Number is Specified
If you specify a slot number after the command syntax, power supply information for only the correspond-
ing switch displays. For example:
-> show power 2
Power Supplies in chassis 2
PS    Operational Status
-----+-------------------
PS-1   UP
PS-2          NOT PRESENT
In the example above, power supply status for the switch operating in slot 2 displays. No backup power 
supply is installed in the slot 2 chassis (or the backup power supply is powered off). 
No Slot Number is Specified
If you do not enter a slot number, power supply information for all switches in the stack displays. For 
example:
-> show power
Power Supplies in chassis 1
PS    Operational Status
-----+-------------------
PS-1   UP
PS-2   UP
Power Supplies in chassis 2
PS    Operational Status
-----+-------------------
PS-1   UP
PS-2          NOT PRESENT
The example above shows the power supply status for a stack consisting of two switches. A backup power 
supply is present and running in the switch operating in slot 1; no backup power supply is installed in the 
switch operating in slot 2 (or the unit is powered off). 
More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 
Family switches, refer to