Alcatel-Lucent omniacces-voip gateway User Manual

Page of 430
 VoIP Commands
Page 5-119
Command Usage
Specify Foreign Exchange Office (FXO) Loop Start allowed time period after a call when a 
channel cannot originate, but may receive a call.
Syntax Options
Remarks
The 
voice signaling protocol
 command must be set to the corresponding protocol type before 
any commands for E&M (Wink Start, Immediate Start, and Delay Start Signaling), and FXS/
FXO (Loop and Ground Start) commands will take effect.
voice signaling fxo ls guard out
voice signaling channel <
slot/port/startChannel-endChannel
 > fxo ls guard out <
value 
>
Definitions: 
slot
Specifies chassis slot number where VSM is installed, (e.g., 
2
).
port
Specifies physical port number on voice daughtercard, (e.g., 
1
).
startChannel
The first number in the range of voice channels (e.g., 
1
).
endChannel
The last number in the range of voice channels (e.g., 
30
).
 Syntax Note 
Be sure to separate the start and end range numbers with a 
hyphen (e.g., 
1-30
).
value
Specifies the fxs ls guard out allowed time period, in milliseconds from 1 to 60,000 (e.g., 
2000) after a call, when a channel cannot originate but may receive a call.
 Syntax Notes 
Do not use commas when entering the duration of the fxo ls 
guard out value (for example, 
10,000
 will return a syntax error 
message).
Default:
The default value is 
2000
 milliseconds.
Command Examples:
voice signaling channel 2/1/1-12 fxo ls guard out 50
voice signaling channel 2/2/13-24 fxo ls guard out 5
voice signaling channel 2/2/1-30 fxo ls guard out 1000