Alcatel-Lucent omniacces-voip gateway User Manual
VoIP Commands
Page 5-170
Command Usage
Override call signaling for QSIG information element (IE) transport (on/off). This command
should only be used under the supervision of trained personnel.
should only be used under the supervision of trained personnel.
Syntax Options
voice signaling override qsig information element transport
voice signaling channel <
slot/port/startChannel-endChannel
> [no] override qsig information
element transport {on | off}
Definitions:
slot
slot
Specifies chassis slot number where VSM is installed, (e.g.,
2
).
port
Specifies physical port number on voice daughtercard, (e.g.,
1
).
startChannel
The first number in the range of voice channels (e.g.,
1
).
endChannel
The last number in the range of voice channels (e.g.,
30
).
♦ Syntax Note ♦
Be sure to separate the start and end range numbers with a
hyphen (e.g.,
1-30
).
no
Optional command syntax.
♦ Syntax Note ♦
If
no
is used then ON and OFF cannot be specified.
on
Turns ON QSIG information element transport for specified telephony signaling channel.
off
Turns OFF QSIG information element transport for specified telephony signaling channel.
♦ Syntax Notes ♦
If this command is set to ON, then call signaling for the Informa-
tion Element must be set to OFF via the
tion Element must be set to OFF via the
override call signaling for
ie transport
command.
Default:
The default setting is
The default setting is
no override qsig information element transport
.
Command Examples:
voice signaling channel 2/1/1-12 no override qsig information element transport
voice signaling channel 2/2/13-24 override qsig information element transport on
voice signaling channel 2/3/1-30 override qsig information element transport off
voice signaling channel 2/2/13-24 override qsig information element transport on
voice signaling channel 2/3/1-30 override qsig information element transport off