   P2000MAN.DOC  19/10/99 17:59
 Use the Assign Action and Assign Timecode menus to fill in the empty
step. See Sections 17.4.1 The Assign Action menu and 17.4.2 The
Assign Timecode menu
 for details.
17.7 Script File Parameters
These are functions that allow the Pearl to automatically execute a Script
File when it is powered up. The Script File can then run once, or loop
continuously. This can be useful for exhibitions and similar installation – type
situations.
To access the Script File Parameters :
 Turn the Key to System. 
Puts you in System Mode
.
 Press Softbutton D [SCRIPT FILE PROGRAMMING].
 Puts you in the Script
File menu
 
and automatically puts you into the Script File Screen (Screen 8).
 Press Softbutton G [SCRIPT FILE PARAMETERS]
. Puts you in the
Execution Modes menu, and automatically goes to Screen 12, SCRIPT FILE PARAMS.
17.7.1 To automatically execute a Script File on Power Up
17.8 Explanation of other Script File commands
17.8.1 Reset Timer
This is only available when Internal timers are being used and it resets the
timer to the last entered time from the select timer menu.
17.8.2 Reset Masters
This releases Playback Faders that are under the control of Timecode.
When pressed the output on stage may be blacked out! Beware!!
17.9 Recalling your Script File
 Turn the Key to Run.
 Press Softbutton D [RUN SCRIPT FILE].
 Enter the number of the Script File you want to autoexecute onto the
Keypad or use the Up and Down Cursor Keys to highlight the Script File
you want.
 Press Softbutton A [TOGGLE AUTORUN]. The prompt line says that
Autorun is ENABLED, and the AUTO column shows that for this Script
File, Auto is ON.
17.7.2 To set a Script File to LOOP
This can only be done with a Script File running from the Internal Clock, as
the clock gets reset each time the Script File runs.
 Enter the number of the Script File you wish to loop onto the Keypad or
use the Up and Down Cursor Keys to highlight the Script File you want.
 Press Softbutton B [TOGGLE LOOP MODE]. The prompt line changes
from saying that the Script File will Stop on final step to saying that it is
Continuous. The LOOP column shows that this Script File ENDS or runs
CONT(inuously).