AXIS 231D+/232D+ - System Options
RTP (Multicast)/MPEG-4
These settings are the IP address, port number, and Time-To-Live value to use for the video 
stream(s) in multicast MPEG-4 format. Only certain IP addresses and port numbers should 
be used for multicast streams. For more information, please see the online help.
Ports & devices - I/O Ports
The pinout, interface support and the control and monitoring functions are described in the 
Maintenance
• Restart - The unit is restarted without changing any of the settings. Use this method if 
the unit is not behaving as expected.
• Restore - The unit is restarted and most current settings are reset to factory default val-
ues. The settings that will not be reset are as follows:
• the boot protocol (DHCP or static)
• the static IP address
• the default router
• the  subnet  mask
• the system time
• Default - The default button should be used with caution. Pressing this will return all of 
the network camera's settings to the factory default values (including the IP address).
Dome Status - Click the Test button to check the camera and dome mechanics for errors. 
Contact Axis Customer Services if you receive an error message as the result of this test.
Upgrade Server - See Support, on page 40.
Backup - To take a backup of all of the parameters, and any user-defined scripts, click this 
button. If necessary, it is then possible to return to a previous configuration if settings are 
changed and there is unexpected behavior.
Restore - click the Browse button to locate the saved backup file (see above) and then click 
the Restore button. The settings will be restored to the previous configuration.
Note: 
Backup and Restore can only be used on the same unit running the same firmware. This feature is not 
intended for multi-configurations or for firmware upgrades.