Apogee x-digi-mix card User Manual

Page of 12
APOGEE ELECTRONICS
8
X-Digi-Mix – User’s Guide
To record at a higher resolution sample rate:
1) Create a Pro Tools session whose sample rate is half the desired rate (i.e., create a 44.1kHz 
session to record 88.2kHz audio.
2) Once the Apogee interface has recognized the sample rate of the session, manually set it to the 
desired high resolution sample rate. When using more than one Apogee interface, the Slave 
interfaces must be clocked from the Master Word Clock Output. 
3) For every track of high resolution audio desired, create a stereo track in the session. Routing of 
audio is as depicted below:
4) Keep in mind that it’s possible to run one interface at a lower sample rate (for example to play back 
tracks), and a second interface at a higher sample rate (for example to record an analog mix of the 
tracks being played back).
Working with ProTools - 
continued
ROSETTA 800 Analog In
Session Tracks 
(and I/O routing)
ROSETTA 800 Analog Out
Input 1
Tracks 1-2
Output 1
Input 2
Tracks 3-4
Output 2
Input 3
Tracks 5-6
Output 3
Input 4
Tracks 7-8
Output 4