3com 3C16751 User Manual

Page of 8
5
Connecting Another OfficeConnect Hub
You may wish to connect another OfficeConnect hub 
to your Dual Speed Hub 16. Alternatively, you may 
wish to add your Hub to an existing 10Mbps 
network. When extending your network, you should 
be aware of the configuration rules given below.
If you connect two Dual Speed Hub 16 units directly 
together, the link between them operates at 100Mbps.
Fast Ethernet (100Mbps) Configuration Rules
The Dual Speed Hub 16 is a Class II hub. You can 
connect directly two Class II Fast Ethernet hubs 
(Class I Fast Ethernet hubs cannot be connected 
directly to other Fast Ethernet hubs). The total length 
of cable (A + B + C below) between two 
workstations, or between a workstation and a 
non-repeater piece of equipment (such as a switch), 
must not exceed 205m (672ft). Each cable (A, B, or 
C) must not exceed 100m (328ft).
3Com recommends that the cable (B) between the 
Fast Ethernet hubs is no longer than 5m (16.4ft). 
This allows the maximum hub-to-workstation cable 
length (A or C) of 100m (328ft) to be used, as shown 
in the example.
Configuration Rules and Example of a Fast Ethernet (100Mbps) Network
Ethernet (10Mbps) Configuration Rules
You can connect a maximum of four Ethernet 
(10Mbps) hubs in series between workstations, or 
between a workstation and a non-repeater piece of 
equipment (such as a switch). Each cable must not 
exceed 100m (328ft). An example is shown below.
Example of Ethernet (10Mbps) Network
Making the Connection to Another Hub
You can connect a 10BASE-T, 100BASE-TX, or 
another 10/100BASE-TX OfficeConnect hub to any 
port on the Dual Speed Hub 16. Use the following 
method:
1
Using a straight-through cable, connect the 
MDI/MDIX port of the Dual Speed Hub 16 to any of 
the ports on the other hub (as shown in the diagram 
below). If using an MDI/MDIX port on the other hub, 
set its MDI/MDIX switch to MDIX (out).
2
Set the MDI/MDIX switch for the MDI/MDIX port on 
the Dual Speed Hub 16 to MDI (in).
Correct Connections for OfficeConnect Hubs
Powering Up and Checking Connections
When you have connected all the appropriate 
workstations and other equipment to the Hub, power 
on the Hub. For each port with a connection, the 
corresponding Port Status LED should be on. If the 
LED is off, check your connections.
CAUTION: Do not power the Hub off and on quickly. 
Wait about 5 seconds between power cycles.
Spot Checks
At frequent intervals, visually check that:
The Alert LED is off — this is the best way to find out 
if there are problems with your network
Case vents are not obstructed
Cabling is secure and not pulled taut
If you suspect a problem, refer to “Problem Solving” 
on page 7
.