Configuring and Managing the System Log
625
Using Log Commands
To enable, disable, or modify system logging to the WX switch’s log 
buffer, console, current Telnet session, or trace buffer, use the following 
command:
set log {buffer | console | current | sessions | trace
[severity severity-level] [enable disable]
To configure system logging to a syslog server, use the following 
command:
set log server ip-addr [port port-number] severity 
severity-level [local-facility facility-level]
To enable periodic mark messages for use in troubleshooting, use the 
following command:
set log mark [enable | disable] [severity level
[interval interval]
To view log entries in the system or trace buffer, use the following 
command:
display log buffer | trace
To clear log messages from the system or trace buffer, use the following 
command:
clear log buffer | trace
To stop sending messages to a syslog server, use the following command:
clear log server ip-addr
notice
Events that potentially can cause system problems have 
occurred. These are logged for diagnostic purposes. No 
action is required.
info
Informational messages only. No problem exists.
debug
Output from debugging.
The debug level produces a lot of messages, many of which 
can appear to be somewhat cryptic. Debug messages are 
used primarily by 3Com for troubleshooting and are not 
intended for administrator use.
Table 54   Event Severity Levels (continued)
Severity
Description