3com WX2200 3CRWX220095A User Manual

Page of 728
Configuring and Managing Ports
75
For the serial-id parameter, specify the serial ID of the MAP. The serial ID 
is listed on the MAP case. To display the serial ID using the CLI, use the 
display version details command.
The model and radiotype parameters have the same options as they do 
with the set port type ap command. Because the WX does not supply 
power to an indirectly connected MAP, the set ap command does not 
use the poe parameter. 
To configure a connection for MAP 1, which is a MAP model MP-372 
with serial-ID 0322199999, type the following command:
WX# set ap 1 serial-id 0322199999 model mp-372
success: change accepted.
Setting a Port for a Wired Authentication User
To set a port for a wired authentication user, use the following command:
set port type wired-auth port-list [tag tag-list
[max-sessions num]
You must specify a port list. Optionally, you also can specify a tag-list to 
subdivide the port into virtual ports, and set the maximum number of 
simultaneous user sessions that can be active on the port. By default, one 
user session can be active on the port at a time. 
The fallthru authentication type is used if the user does not support 
802.1X and is not authenticated by MAC authentication. The default is 
none, which means the user is automatically denied access if neither 
802.1X authentication or MAC authentication is successful.
To set port 17 as a wired authentication port, type the following 
command:
WX1200# set port type wired-auth 7
success: change accepted
Table 7   Valid dap-num Values
Switch Model
Valid Range
WX4400
1 to 300
WX1200
1 to 30
WXR100
1 to 8
WX2200
1 to 320