3com 1600 User Manual

Page of 8
Unit Connections
To connect OfficeConnect units (such as hubs and 
switches) to your Switch, you need:
One suitable TP cable for each unit.
Workstation Connections
To connect workstations or other equipment (such as 
servers) directly to your Switch, you need:
1
One 10BASE-T, 100BASE-TX 
or 10/100BASE-TX adapter 
card for each workstation. 
3Com produce a range of 
easy to install network 
adapters, which provide your 
workstation with a 10BASE-T 
or 100BASE-TX connection.
2
One suitable TP cable for each workstation.
In order to comply with the 10BASE-T standard, ports 
designed for workstation connections have been 
marked with the graphical symbol ‘x’. This denotes a 
crossover in the port’s internal wiring, for example 1x, 
2x, 3x...
You also need a network operating system running 
on your workstations.
Twisted Pair (TP) Cables
To connect your hubs and workstations to the Switch, 
you must use ‘straight-through’ TP cables with RJ-45 
connectors (all OfficeConnect products use RJ-45 type 
connectors). Your supplier should stock suitable 
cables.
A ‘straight-through’ cable is one where each pin of 
one connector is connected to the same pin of the 
other connector.
Cables can be shielded (screened) or unshielded; we 
recommend that you use shielded cable. Cables used 
for 100BASE-TX connections must be data grade 
(Category 5). The maximum length you can use is 
100m (328ft).
Positioning Your OfficeConnect Switch
When installing your OfficeConnect Switch, ensure:
It is out of direct sunlight and away from sources of 
heat.
Cabling is away from power lines, fluorescent lighting 
fixtures, and sources of electrical noise such as radios, 
transmitters and broadband amplifiers.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents in the 
side of the case is not restricted. We recommend you 
provide a minimum of 25mm (1in.) clearance.
Using the Rubber Feet and Stacking Clips
The four self-adhesive rubber feet prevent your 
Switch from sliding around on your desk. Stick the 
feet to the marked areas at each corner of the 
underside of your Switch.
The four stacking clips are used for neatly and 
securely stacking your OfficeConnect units together. 
You can stack up to four units. Small units must 
be stacked above large units.
 To stack your units, 
secure the clips on one side and then on the other. 
Use the following method to secure one side:
1
Place your new unit 
on a flat surface. 
Your clips fit in these 
positions on the side 
of the unit:
2
Position a clip over 
one of these holes and 
push it in until it clicks 
into place. Repeat this 
for the other clip 
position on the same 
side.
3
Keeping the front of 
the units aligned, rest 
the bottom of the 
existing unit on the 
clips’ spikes. Push the 
clips firmly into the 
existing unit until they 
click into place.
Repeat these steps to secure the other side.
To remove a clip, hold the units firmly with one hand 
and hook the first finger of your other hand around 
the back of the clip. Use reasonable force to pull it off.