ATIKA ale 600 Brochure

Page of 82
 
15
W
W
a
a
t
t
e
e
r
r
 
 
o
o
u
u
t
t
l
l
e
e
t
t
 
 
 
The water collecting container of the air dehumidifier is 
equipped with a float switch which turns off the device when 
the collecting container is full. 
 
L
  After 45 seconds, compressor and fan will automatically 
stop, and an acoustic signal will sound. The 
 icon and 
the fault code E4  will be displayed.  
 
 
Another acoustic signal will sound every 5 minutes if the 
water collecting container is not immediately emptied.  
 
 
 
Removing the water collecting container
 
 
1.  Turn off the device. 
2.  Press on the hinged cover (1)   and open it then  . 
 
3.  Remove the container (pos. 2) and empty is immediately. 
 
 
 
 
 
 
 
 
 
 
 
4.  Re-insert the container. When inserting put the draining 
hose (3) into the water collecting container. Make sure that 
the container is correctly positioned.
 
 
5.  Close the hinged enclosure cover. 
6.  Restart the air dehumidifier. The 
 icon and the fault 
code E4 should no longer be displayed. 
 
Icon and fault code are further displayed? Remove the 
container again and re-insert it properly.
 
 
 
Continuous or extended operation 
In the case of a high humidity of air it is recommended to 
operate the air dehumidifier in continuous mode. In continuous 
mode it is not needed to empty the water collecting container.
 
Proceed as follows: 
1.  Remove the water collecting container from the device. 
2.  Put the draining hose (3) through the hole   in the 
enclosure and pull it out of the device on the other side  
 
3.  Re-insert the collecting container in the device. 
4.  Close the hinged enclosure cover. 
5.  Place a large collecting container below the water draining.  
 
Or: 
Extend the water draining using a garden hose to pipe the 
water into a drain channel.