act actsmart standalone Assembly Instruction
OMR
O N
5A 2
50
V
AC
5A 3
0V DC
+
O
MR
ON 1
A 1
2
5
V
A
A
C
1
A 3
0
V
D
C
Door
Contact
Contact
Door Release Button
12-24V
DC/AC
0V
N/ O
COMM
N/ C
B
A
Aux I/O 2
Tamper
This illustration shows wiring
for normally de-energised locks.
If normally energised locks are
required, use the N/C relay contact.
for normally de-energised locks.
If normally energised locks are
required, use the N/C relay contact.
0 1 2 3 4 5 6 7 8 9
BATCH:
PRODUCT
:
SERIAL NUMBER
:
01XX-
ACTSmart REV1.3
00XXX
Important!
Always Place Varistor
Across Lock Terminals
Across Lock Terminals
Volt-Free
Tamper Contacts
Tamper Contacts
+12V
0V
Power
Supply Unit
+V
Sounder
The Aux I/O Output is an open
collector output capable of
sinking 100mAmps.
collector output capable of
sinking 100mAmps.
Note: To program the various Input and
Output operations for the ACTSmart unit,
please refer to page 10.
Output operations for the ACTSmart unit,
please refer to page 10.
Aux I/O 1
Default configuration for
AUX I/O 1 is Door Contact.
AUX I/O 1 is Door Contact.
S
C
H
R
A
C
K
1
2
V
=
D
C
5
A
/2
5
0
V
~
A
C
Programmable
Input
The ACTSmart may be powered
from 12 or 24V AC or DC for
Standalone operation.
from 12 or 24V AC or DC for
Standalone operation.
Default configuration
for Programmable Input
is Door Release Button.
for Programmable Input
is Door Release Button.
ACTSmart Standalone Installation Diagram
- 15 -
Default configuration for
AUX I/O 2 is Door Alarm.
AUX I/O 2 is Door Alarm.
- 1
5
-