ADC megabit modem 310f User Manual

Page of 68
Configuring ADSL Service
 
24
Megabit Modem 310F and 320F User Manual
Configuring Alarms
You can configure the severity of each modem alarm, or disable alarms.
1
From the 
ADSL Configuration Menu
), type 
 to select 
Alarm Configuration
.
2
Type 
 to move to the next alarm type until you select the one you want to configure.
The following table identifies the available alarm types.
3
Press the 
 to toggle to the setting you want for the alarm, then press 
The following table describes the available alarm settings. The default for each alarm is E.
Alarm Type 
Description
LOF
Loss of Frame
MAR
Margin
ES
Errored Seconds
SES
Severely Errored Seconds
LOS
Loss of Signal
SELF
Self test failed
Setting
Description
E
Enables the alarm as a minor alarm.
M
Enables the alarm as a major alarm.
D
Disables the alarm.
9
N
SPACEBAR
ENTER