HP omnibook 4000 Service Manual

Page of 53
___________
46
3-1-2
Master DMA register test in progress or failure.  Failure results
in a system halt.
3-1-3
Master interrupt mask register test in progress or failure.
Failure results in a system halt.
3-1-4
Slave interrupt mask register test in progress or failure.
Failure results in a system halt.
3-2-4
Keyboard controller test in progress or failure.  Failure results
in a system halt.
3-3-4
Screen memory test in progress or failure.  Failure will result
in a beep code but not a system halt.
3-4-1
Video Retrace Failure.
3-4-2
Screen retrace test in progress.
3-4-3
Screen retrace test  failure
4-2-1
Timer-tick interrupt test in progress or failure.  An error
message is displayed on the screen.  The system does not
halt.
4-2-2
Shutdown test in progress or failure.  If possible, the BIOS will
continue POST, skipping the memory tests.
4-2-3
Gate A20 failure. An error message is displayed on the screen
and the memory tests are suspended.  The system does not
halt.
4-2-4
Unexpected interrupt in protected mode. The system does not
half when an unexpected interrupt occurs.
4-3-1
RAM test of memory above 64K in progress or failure.  POST
will continue.
4-3-2
Programmable interval timer channel 2 test in progress or
failure.  POST will continue.
4-3-4
Real-time clock text in progress
4-4-1
Serial port test in progress or failure.  POST will continue.
4-4-2
Parallel port test in progress or failure.  POST will continue.
4-4-3
Math coprocessor test in progress or failure.  POST will
continue.