II. TROUBLESHOOTING
Causes and corrective actions against possible faulty image and faulty operation are listed
below.
A. Faulty Image
1. Image not output
Cause 1
: Faulty connection of the USB cable
Corrective action : Securely connect the USB cable.
Cause 2
: Faulty scanning lamp when scanning in flatbed mode
Corrective  action : Replace the lamp unit.
Cause 3
: Faulty FAU when scanning a film
Corrective action : Replace the document cover.
Cause 4
: Faulty CCD
Corrective action : Replace the scanning unit.
Cause 5
: Faulty main PCB
Corrective  action : Replace the main PCB.
2. Uneven image density or lines
Cause 1
: Dirt on the document cover or document glass
Corrective action : Clean the document cover or document glass.
Cause 2
: Faulty calibration data
Corrective  action : Scan again.
Cause 3
: External light is entering into the scanner. External light entering into
the CCD can cause uneven image density.
Corrective  action : Fully close the document cover. If it is impossible, cover with a sheet etc.
to prevent external light.
Cause 4
: Faulty CCD
Corrective action : Replace the scanning unit.
Cause 5
: Faulty main PCB
Corrective  action : Replace the main PCB.