Nikon COOLPIX 4500 Maintenance Manual
VAA11901-R.3579.A
- A11 ・ E4500 -
9. Calibration software
After starting the applicable calibration software, the following is displayed on the PC monitor.
10. Lens Adjustment
[Preparation]
• Siemens star chart
• POWER switch: ON
• POWER switch: ON
[Adjustment condition]
• Make a copy of A4 size siemens chart in enlarged A3 size or larger.
• Illumination above the subject should be 400 lux ± 10 %.
• Set the siemens star chart 150 cm ± 3 cm (between Siemens star chart and the surface of camera’s
protection lens)
• Illumination above the subject should be 400 lux ± 10 %.
• Set the siemens star chart 150 cm ± 3 cm (between Siemens star chart and the surface of camera’s
protection lens)
[Adjustment method]
1. Double-click on the DscCalDi128.
2. Set the siemens star chart 150 cm ± 3 cm so that it be-comes center of the screen. LCD (Test → Monitor)
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
ADJ_AFPOS = 0 ± 70 ADJ_PZPOS = 0 ± 70
5. Click the OK.
2. Set the siemens star chart 150 cm ± 3 cm so that it be-comes center of the screen. LCD (Test → Monitor)
3. Click the Focus, and click the Yes.
4. Lens adjustment value will appear on the screen.
ADJ_AFPOS = 0 ± 70 ADJ_PZPOS = 0 ± 70
5. Click the OK.
“Yes”
Adjustment value