Juniper CBL-M40-PWR-AU User Manual

Page of 268
Troubleshoot PICs
M40 Internet Router Hardware Guide
202
For more detailed output, add the 
detail
 option. The following example also specifies a 
slot number (
0
), which is optional:
user@host> show chassis fpc detail 0
Slot 0 information:
  State 
Online    
  Logical slot 
0
  Temperature 
28 degrees C / 82 degrees F
  Total CPU DRAM 
8 MB
  Total SRAM 
1 MB
  Total SDRAM 
128 MB
  Total notification SDRAM 
24 MB
  I/O Manager ASIC information 
Version 1.1, Foundry IBM, Part number 0
  Start time: 
2003-05-23 18:14:31 PDT
  Uptime: 
 34 days, 6 hours, 9 minutes, 5 seconds
Troubleshoot PICs
To troubleshoot PICs, follow these guidelines:
„ To check the status of each port on a PIC, look at the LED located on the PIC faceplate. 
For information about the meaning of LED states on different PICs, see the M20 and M40 
Internet Routers PIC Guide
.
„ To check the status of a PIC, issue the following CLI command. The following example 
specifies an FPC slot number (
3
), which is optional. The PIC slots in the FPC are 
numbered from 
0
 (zero) through 
3
, top to bottom:
user@host> show chassis fpc pic–status 3
Slot 3 Online
PIC 0    4x OC-3 SONET, MM
  PIC 1    4x OC-3 SONET, SMIR
  PIC 2    1x OC-12 SONET, SMIR
  PIC 3    1x G/E, 1000 BASE-SX
Troubleshoot the SCB
To troubleshoot the SCB, follow these guidelines:
„ Periodically check the alarm LEDs and the LCD on the craft interface. If the SCB is not 
functioning properly, it might send spurious error messages to the Routing Engine 
(indicating incorrectly that system components are malfunctioning, for example). These 
messages can appear on the LCD.
„ If all four LEDs on the SCB faceplate are on, but dimly lit, the SCB is probably not seated 
properly. Tighten the captive screws at the top and bottom of the SCB card carrier. For 