Sony bg3r chassis kv-ar29k90 Service Manual

Page of 99
– 14 –
KV-AR29K90
RM-996
(3) Screen-corner Convergence
Fix a Permalloy assy corresponding to the misconverged
areas.
3-3. FOCUS ADJUSTMENT
FOCUS adjustment should be completed before W/B adjustment.
1.
Receive digital monoscope pattern.
2.
Set "Picture Mode" to "Standard".
3.
Set S2801 to mechanical center position.
4.
Adjust focus VR so that the center of the screen becomes just
focus.
5.
Adjust S2801 when corner focus is unbalance is right and left.
6.
Change the receiving signal to white pattern blue back.
7.
Confirm Magenta ring is not noticable. Incase magneta ring is
obvious, reset S2801 to mechanical center position and then
adjust FOCUS VR to balance between MAGENTA RING and
FOCUS.
TLV
Rotate
TLV-2 VOL (29”, 34”) on DY
XCV
Rotate
XCV
Adj core on DY
YCH
Rotate
YCH
VOL on DY
TLH
Insert
TLH
Correction Plate to DY Pocket
(Left or Right)
ON DY:
FLYBACK TRANSFORMER  (T503)
YCH
XCV
TLV1
TLV2
b
a
c
d
a-d : screen-corner
        misconvergence
a
b
c
d
Permalloy assembly
Focus
Screen