Sony BKP-7933 User Manual

Page of 56
1-33 (E)
BKP-7933
1-7-10. Returning the Setups of the MODIFICATION COMMAND to the Factory
Default Values
1.
Select “K: RESET TO DEFAULT TABLE” using the
cursor key and press [ENTER].
2.
The message “Reset to Default table?” appears in the
bottom right of the screen.  Select “Y” and press
[ENTER].
SONY ROUTING SYSTEM SETUP MENU         BKP-7933 V1.00      STATION NUMBER 2
   
                         MODIFICATION COMMAND
 A: SET UNIT LOCATION(CAM-CCU)          B: SET UNIT LOCATION(CCU-RCP)
 C: SET UNIT LOCATION(MSU)
 K: RESET TO DEFAULT TABLE
                         MAINTENANCE COMMAND
 Z: BKP-7933 CONFIGURATION
 Ctrl-D RETURN
1-7-11. Returning the Setups of the MAINTENANCE COMMAND to the Factory
Default Values
1.
Establish the following setup of the switch S2 on the
IF-689 board depending upon the type (analog/digital)
of routing switcher.
S2-1:
When the analog routing switcher (BVS-V3232) is used
 ON
When the digital routing switcher (DVS-V1616) is used
 OFF
S2-2 to S2-8: OFF
Factory default setting :
All OFF
2.
Set the switch S5 on the IF-689 board as shown below.
S5-1 to S5-3:OFF
S5-4:
ON
S5-5:
ON
S5-6 to S5-8:OFF
Factory default setting:
All OFF
3.
Turn on the main power of the CNU-700, or press the
RESET switch S1.
n
All data is initialized in about five seconds.
4.
Set the switch S5 to the factory default position.
1-7. Setting Up
IF
RX TX
S-BUS
S-BUS ID No.
S5
S2
S1
CNU GROUP No.
+5
(Component side/A side)
IF-689 board
1
8
7
6
5
4
3
2
(      indicates the switch lever position)