Sony BKAM-101 User Manual

Page of 10
1-3(E)
AMS-100
1-4. Rack Mounting
The AMS-100 can be mounted in a 19-inch standard rack.
n
. If the AMS-100 or the peripheral equipment is mounted
in a 19-inch standard rack, it is recommended to install a
ventilation fan to prevent a temperature rise in the rack.
Make sure that all the units in the rack should be operat-
ed within the temperature range of 5
dC to 40dC.
. Connect the enough long cables on the rear panel,
considering that the AMS-100 is pulled out.
. Be sure to fix the rack to the floor with bolts.
This will prevent the rack from falling when the unit is
pulled out from the rack.
Required parts
. Rack mount rail (RMM-30)
Rail with bracket
: 2 pcs.
Screw (B5
x8)
: 4 pcs.
Screw (PWH4
x10)
: 2 pcs.
Plate nut
: 2 pcs.
. Screw for inner rail (B4x8)
: 6 pcs.
. Screw for rack mounting (RK5x16) : 4 pcs.
. Washer for rack mounting
: 4 pcs.
(Sony part number : 2-297-913-00)
c
Be sure to use the RMM-30 rack mount rail.
If a rack mount rail other than the RMM-30 is used, the
AMS-100 may be dropped by insufficient strength of the
rack mount rail.  This may cause a injury.
Procedures
1.
Turn off the power.
2.
Attach the inner rails to the unit using the six screws
(B4
x8) supplied with the RMM-30.
3.
Temporarily fix the front and rear brackets to the rack
by running in but not tightening the four screws
(B5
x8) and two screws (PWH4x10) supplied with the
RMM-30.
_To be continued on the next page._
B 4
x
8
B 4
x
8
Inner rail
Inner rail
1-4. Rack Mounting
PWH 4
x
10
Plate nut
15.9
15.9
12.7
15.9
15.9
12.7
Rack
B 5
x
8
Front bracket
Rear bracket
31.75