Five-digit display
Cause and/or Corrective Actions
• Moisture condensation has occurred.
m Remove the cassette and leave the camcorder for at least
1 hour. (p. 57)
• The video heads are dirty.
m Clean the heads using the Sony V8-25CLDcleaning
cassette (not supplied). (p. 58)
• You are using a battery pack that is not an
“InfoLITHIUM” battery pack.
m Use an “InfoLITHIUM” battery pack. (p. 56)
• A serviceable situation not mentioned above has occurred.
m Remove the cassette and insert it again, then operate the
camcorder.
m Disconnect the power cord of the AC power adaptor or
remove the battery pack. After reconnecting the power
source, operate the camcorder.
• A camcorder malfunction which you cannot service has
occurred.
m Contact your Sony dealer or local authorized Sony
service facility and inform them of the five digits.
(example: E:61:10)
The camcorder has a self-diagnosis display.
This function displays the camcorder‘s condition
with five digits (a combination of a letter and
figures) in the viewfinder or in the display
window. If this occurs, check the following code
chart. The five-digit display informs you of the
camcorder‘s current condition. The last two digits
(indicated by 
ππ) will differ depending on the
state of the camcorder.
Self-diagnosis display
C:21:
ππ
If you are unable to resolve the problem, contact your Sony dealer or local authorized
Sony service facility.
Viewfinder
Self-diagnosis display
•C:
ππ:ππ
You can service the camcorder
yourself.
•E:
ππ:ππ
Contact your Sony dealer or local
authorized Sony facilitiy.
C:21:00
E:61:
ππ
E:62:
ππ
C:31:
ππ
C:32:
ππx
C:23:
ππ
C:22:
ππ