Sony CDX-GT50W User Manual

Page of 36
14
Fuse replacement
When replacing the fuse, be 
sure to use one matching the 
amperage rating stated on the 
original fuse. If the fuse blows, 
check the power connection and 
replace the fuse. If the fuse 
blows again after replacement, 
there may be an internal 
malfunction. In such a case, 
consult your nearest Sony 
dealer.
Cleaning the connectors
The unit may not function properly if the connectors 
between the unit and the front panel are not clean. In 
order to prevent this, detach the front panel (page 4) 
and clean the connectors with a cotton swab dipped 
in alcohol. Do not apply too much force. Otherwise, 
the connectors may be damaged.
Notes
• For safety, turn off the ignition before cleaning the 
connectors, and remove the key from the ignition 
switch.
• Never touch the connectors directly with your fingers 
or with any metal device.
Removing the unit
1
Remove the protection collar.
1
Detach the front panel (page 4).
2
Engage the release keys together with the 
protection collar.
3
Pull out the release keys to remove the 
protection collar.
2
Remove the unit.
1
Insert both release keys simultaneously 
until they click.
2
Pull the release keys to unseat the unit.
3
Slide the unit out of the mounting.
Specifications
Fuse (10A)
Main unit
Back of the front 
panel
Orient the release 
keys as shown.
Hook facing 
inwards.
AUDIO POWER SPECIFICATIONS
POWER OUTPUT AND TOTAL HARMONIC 
DISTORTION
23.2 watts per channel minimum continuous 
average power into 4 ohms, 4 channels driven 
from 20 Hz to 20 kHz with no more than 5% total 
harmonic distortion.
CEA2006 Standard
Power Output: 17 Watts RMS 
× 4 at 
4 Ohms < 1% THD+N 
SN Ratio: 82 dBA 
(reference: 1 Watt into 4 Ohms)