Sony cis201 User Manual

Page of 27
6
Stop All Data
This command stops all Control-S Continuous data being sent.  This      
must    be sent after any
continuous command has been initiated, otherwise the next command(s) sent will be
ignored.
1 Byte: Attention Byte
<9xH> 90H logically OR’d with ID number.
 CIS-201 Protocol Summary
    
Send Strings
     (x = ID Number)
  Command
    Terminating
 
    
Header          
        
No.   
            
Product Code         
Command          
byte   
Send Control-S Data
<8xH>  <3>  <Chnl>  <Hi>  <Lo>  <Data>  <FxH>
Send Control-S Continuous
<8xH>  <4>  <Chnl>  <Hi>  <Lo>  <Data>  <FxH>
Stop ALL Data
<9xH>
CONTROL-S PRODUCT CODES
     
HI   
   
 byte       
    
LO
    
   
 byte   
       
PRODUCT
00
10
TV
00
12
VCR 1
00
13
VCR 2
00
14
VCR 3
00
17
LDP
00
1A
PROJECTOR
00
40
AMP
00
41
AUDIO TUNER
00
42
AUDIO SYS / PREAMP
00
43
SOUND ADAPTOR
00
44
CD 1
00
45
CD 2
00
46
CD 3
00
47
MD
00
48
TAPE
00
49
DAT
00
60
DST
00
61
DSS
01
2B
DVD
02
2B
AC3 PROCESSOR
The following pages contain every available code for each product category.  Since 