Sony cis200 User Manual

Page of 66
Correspondence between Request and Answer Codes
Category: MD1, MD2
Control-A1
Product Code : 90, 91
REQ
ANS
CODE NAME
CODE
REQ : 6th byte
REQ : 7th byte
REQ : 8th byte
REQ : 9th byte
REQ : 10th byte
5th byte
3rd byte
LENGTH
ANS : 4th byte
ANS : 5th byte
ANS : 6th byte
ANS : 7th byte
ANS : 8th byte
44
MODEL DATA REQ.
5
74
MODEL DATA
5
Disc count
FEATURE
01 to FF (255)
b7~b2
b1 :
b1 :
000000 fixed
Time Machine REC Recording
0 : OFF
0 : OFF
1 : ON
1 : ON
0E
STATUS REQ.
5
51
STATUS DATA
8
DATA1
DATA2
DISC No.
TRACK NO.
b7b7 
b7 : TOC
01 to FF (255)
01 TO FF (255)
00 fixed
0 : not yet read
00 is current disc
b5 : NO DISC?
1 : read ended
0 : DISC LOADED  b6 :
1 : NO DISC
0 : 1 DISC mode
b4 POWER
1 : ALL DISCS
0 : ON 
b5 :
1 : OFF
0 : REC disabled
b3b2b1b0 :
1 : REC ENABLED
0000 : STOP
b4b3 : 
0001 : PLAY
00 : REPEAT off
0010 : PAUSE
01 : REPEAT all
0011 : EJECT
10 : REPEAT 1
0100 : REC PLAY
11 : REPEAT A-B
0101 : REC PAUSE b2b1b0 :
0110~1110 rsrvd
000 : CONTINUE
1111 playback
001 : SHUFFLE
           impossible
010 : PROGRAM
011~111 reserved
• • •
33
PGM TOP (access ended)
7
DISC No.
TRACK NO.
MIN
SEC
Equivalent to in-program code, 
01 to FF (255)
01 TO FF (255)
MIN, SEC are BCD code.  However, for
and transmitted including the 
00 is current disc
the second digit for minutes:
program length at access end or
A is 100 minutes and F is 150 minutes.
a TNO change.
For example,
123 minutes 50 seconds = C3 50
• • •
34
ELAPSED TIME
7
TRACK NO.
01H FIXED
MIN
SEC
01 TO FF (255)
MIN, SEC are BCD code.  However, for
the second digit for minutes:
A is 100 minutes and F is 150 minutes.
For example,
123 minutes 50 seconds = C3 50
92
• • •
DISC NAME WRITE
21
DISC NO.
ASCII DATA x 16 bytes (the last data is "00H")
01 to FF (255)
00 is current disc
93
• • •
DISC WRITE continue
21
PACKET No.
ASCII DATA x 16 bytes (the last data is "00H")
Returns NON-EXECUTABLE
Hex, 02 or greater
when the data cannot be received
90
• • •
TRACK NAME WRITE
21
TRACK NO.
ASCII DATA x 16 bytes (the last data is "00H")
01 TO FF (255)
91
• • •
TRACK WRITE continue
21
PACKET No.
ASCII DATA x 16 bytes (the last data is "00H")
Returns NON-EXECUTABLE
Hex, 02 or greater
when the data cannot be received
33