Eaton IPC3601-F3-3316 User Manual

Page of 4
© 2008 Eaton Corporation. All Rights Reserved. All specifications are subject to change without notice.
www.pulizzi.com • pulizzisales@eaton.com • 800-870-2248 • Fax: 605-334-4999 
2
  
IPC36XX- Front
CB
IPC3601 Rear
IPC3602 Rear
CHASSIS
1.72” (1U) x Depth 9.5” x Width 19.0”
Weighs approximately 12 lbs.
Powder coated black steel
Detachable mounting brackets allow for 
several mounting options
NEMA or IEC 320 OUTLETS
IPC3601 has 8 IEC 60320 Type 
C13 (computer style) outlets 
IPC3602 has 8 NEMA 5-15R 
(3 prong) outlets
12 INDICATOR LIGHTS
Main power system on
Power “on” to outlets 1-8
2 Data and ethernet link
POWER INPUT
IEC 60320 Type C20 Inlet 
Mating power cables must be  
 
ordered separately
IPC3601 has a full range power  
 
supply for use at 100-240V
EMI/RFI FILTERING
Common Mode - Line to Ground
Differential Mode - Line to Line
Filtered inlet isolates noise before  
 
entering the system
IPC3601-F3-3316 – 
NO FILTER
SPIKE/SURGESUPPRESSION
Line to Neutral (or Line)
OVERLOAD PROTECTION
Push button circuit breaker pops out  
 
when an overload occurs 
Push to reset
SOFTWARE SECURITY
User name/password security
Settings allow the administrator to  
 
disable unused interfaces
SERIAL/ETHERNET
Serial RS232 via RJ22 connector on the 
rear. 6’ RJ22 to DB9 cable included
Serial baud rate is 9600 default or   
 
38,400 maximum
Ethernet (10/100) network via RJ45  
 
connector on the rear. 6’ network 
cable included 
Network setup allows DHCP or any  
 
static public/private IP address
SOFTWARE INTERFACES
Web interface provides a graphic  
 
control interface through a web  
 
browser (IE, Netscape, Mozilla)
Telnet interface provides a text menu    
control interface with any terminal  
 
emulation software  
SNMP allows read/write capability  
 
with trapping
E-mail notification system provides e-mail 
alerts or logs showing user activity
Serial interface provides a text menu    
control interface with any terminal  
 
emulation software
FTP utility allows firmware upgrades 
SOFTWARE FEATURES
Administrator and multiple users can    
be configured
User level access can be limited to  
 
specific outlets
Unit and outlet names can be configured
Outlet groups can be created to  
 
perform an action on multiple outlets
Outlet control includes individual,  
 
group and all outlet global control
Outlet actions include on or off and reboot
Global sequence allows all the  
 
outlets to be turned on or off in a   
 
preset sequence up to 999 seconds
Outlet reboot automatically turns an outlet 
off and back on with one command at a 
preset time up to 999 seconds
E-mail notification allows up to two  
 
e-mail addresses to receive notifications 
of alerts or events
AUTO-EVENT SCHEDULING
Administrator can configure on or off    
events for outlets or groups. The event   
occurs at the preset time daily or weekly 
SPECIFICATIONS
IPC3601
IPC3602
IPC3601-F3-3316
Approvals
CB, CE, UL/cUL Listed, FCC UL/cUL Listed, FCC
NA
Voltage Input/Output (50/60Hz)
100-240V~
120V~
200-240V~
Current Rating
16A
16A
24A
Full Load VA
1920VA @ 120V~
3840VA @ 240V~
1920VA
5760VA
Ethernet/Serial
YES
YES
YES
Outlets
IEC C13
NEMA 5-15R
IEC C13
Circuit Breaker
20A
20A
(2) 15/15A
EMI/RFI Filter
20A
20A
NO
Surge Suppression
YES
YES
YES
Power Input
C20 Inlet
C20 Inlet
Attached
Power Cable/Plug
Not Included
Not Included
10’ - L6-30P