Sony DASK-S704 User Manual

Page of 72
33
(GB)
Error Messages
If an error occurs, the error message appears in the display window.
Error message
Cause
Countermeasure
Please insert MS
Licence code error
Please change Licence MS
No Space on MS[xxxxxxxx]
Delete files or
Change MS and Press F2
This file can’t be overwritten.
Please select another file.
OK?
This MS is new
Press F4 and enter name of MS
Error indicators for the input digital signal
When an error occurs on the input digital signal, the word  SAMPLE or
SETUP and an error indicator flash alternately.  Simultaneously, the F1
key lights or flashes in red.
SAMPLE
Enter
Rehearsal
Sampling
Compile
Change MS
MS:xxxxxxxx  24MB Available
Fs/Period=Fs/5.5sec
Repeat   =16
Input    =AD
Clock    =Internal 48.0 kHz
 Sync
Y
Error indicator
Cause
Countermeasure
Sync
When Word or AES (DI) sync is selected
with Clock Sel, the clock signal frequency
is outside the range between -12.5 % and
+8 % of the sampling frequency.
Valid
Error of the validity bit
Slip
The input signal is not synchronized with
the clock.
CRC
Error of the CRC bit
Parity
Error of the parity bit
Bphase
Error of the bi-phase coding
Unlock
The digital input signal is not locked.
Notes
• When operating with external sync, if you input a clock signal exceeding
+8 % of the sampling frequency, the Sync error indicator is displayed.
Even if you change the clock signal to a correct signal, the Slip error
indicator may appear.  In this case, disconnect the clock input, and
reconnect it.
• The Sync error indicator may appear during rehearsal, sampling or
compiling when the clock is switched.  This is not a problem.
Insert a Memory Stick and press the F2 key or F4
key.
Insert the Memory Stick supplied with the DASK-
S704.
Change the Memory Stick to another one or delete
unnecessary data. (page 16)
Select a memory number with “----------” memory
label and press the F4 key.
Name the Memory Stick. (page 17)
No Memory Stick is inserted or the
inserted Memory Stick is not recognized.
The DASK-S704 Memory Stick is not
inserted.
The memory capacity of the Memory
Stick is not sufficient.
You selected a memory number with
data stored.
You inserted a Memory Stick not named.
Error indicator
Input an appropriate clock signal.
Input a correct digital signal.
Input a correct digital signal.
Input a correct digital signal.
Input a correct digital signal.
Input a correct digital signal.
Input a correct digital signal.