Sony dsr-1600.gb User Manual

Page of 84
66
Troubleshooting
Chap
ter
 6
   Maint
ena
nc
e and
 T
rou
b
le
s
h
oot
ing
Troubleshooting
If an alarm message appears on the monitor screen, or if 
the unit appears to be malfunctioning, please check the 
following before contacting your Sony dealer.
a) In these states, an alarm message appears on the monitor screen and in the 
time counter display.
Tape problem
Symptom
Cause
Remedy
The unit’s tape 
transport control 
buttons (PLAY, F FWD, 
REW, etc.) do not 
work.
The REMOTE button is lit and the 
LOCAL ENABLE menu item is set to 
STOP & EJECT or ALL DISABLE.
 a)
Press the REMOTE button to turn it off, or change the setting 
of the LOCAL ENABLE menu item 
 to ALL 
ENABLE. 
No cassette is loaded.
 a)
Insert a cassette 
.
Time data problem
Symptom
Cause
Remedy
The tape is running, 
but the time data is not 
shown in the time 
counter display.
The U-BIT time data type indicator is lit. Press the COUNTER SEL button to make the COUNTER or 
TC time data type indicator light up.
Monitor problems
Symptom
Cause
Remedy
Data is not 
superimposed on the 
monitor screen.
The CHARA. DISPLAY menu item is 
set to OFF.
Set the CHARA. DISPLAY menu item 
 to ON.
The monitor is not connected to the 
VIDEO OUT 2 (SUPER) connector of 
this unit.
Connect the monitor to the VIDEO OUT 2 (SUPER) 
connector. (You must make this connection to display any 
type of text on the monitor.)
The image on the 
monitor screen is too 
bright.
The 75 
Ω
 termination switch for video 
input on the monitor is in the OFF 
position, or a 75 
Ω
 terminator is not 
fitted to its video input connector.
Set the 75 
Ω
 termination switch to ON or connect a 
terminator.
The image on the 
monitor screen is too 
dark. 
In a video signal loop-through 
connection of video monitors, 75 
Ω
 
termination switches for video input on 
monitors other than the loop-end 
monitor are in the ON position.
Set the 75 
Ω
 termination switches to OFF on all monitors 
other than the loop-end monitor.