Sony DXC-990 User Manual

Page of 180
D:\Nouhin\DXC990UC\320554311DXC990UC\02GB-
DXC990UC\05OPE.fm
masterpage:Left
25
 GB
Shooting
Oper
at
io
n
DXC-990/990P
3-205-543-11 (1)
White balance adjustment errors
If the auto white balance adjustment is not 
successful, an error message appears on the 
screen. If this happens, take the necessary 
measures and perform steps 1 through 8 
again. 
When configuring a multi-camera system, 
adjust all cameras to prevent camera-to-
camera variations in picture tone.
Before making the adjustments outlined 
below, input the same sync signal to all 
cameras.
Connecting the cameras to video 
equipment with phase indication 
capability
When connecting to a special-effects 
generator, a chroma-key unit, or other video 
equipment with phase indication capability, 
the basic adjustment procedure is as follows:
1
Turn on the phase indication 
capability of the connected video 
equipment.
2
Select H. PHASE from the SYSTEM 
menu, and adjust the horizontal phase.
3
Select SC. PHASE from the SYSTEM 
menu, and adjust the subcarrier phase.   
First adjust the subcarrier phase roughly 
with SC. PHASE ROUGH set to 0° and 
180°, then adjust it finely using SC. 
PHASE FINE.
For more details, refer to the instruction 
manual of the connected video 
equipment with phase indication 
capability.
Connecting the cameras to video 
equipment without phase 
indication capability
Use one of the cameras as a reference 
camera and adjust the other cameras to the 
reference camera one by one.
1
Adjust the horizontal phase. Select 
H. PHASE from the SYSTEM menu, 
and adjust so that the reference video 
signal and the output signal have the 
same horizontal sync phase. Use a 
waveform monitor or an oscilloscope 
to check the phase.
2
Adjust the subcarrier phase. Select 
SC. PHASE from the SYSTEM menu. 
First adjust the subcarrier phase roughly 
with SC. PHASE ROUGH set to 0° and 
180°, then adjust it finely using SC. 
PHASE FINE so that the reference video 
signal and the output video signal have 
the same subcarrier phase. Use a 
vectorscope or the wiping function of a 
special-effects generator to display the 
images of both the reference camera and 
the camera to be adjusted 
simultaneously on the screen.
Adjusting the Picture Tone in 
a Multi-Camera System
WHITE:     
NG
             XXXXX
Error message