Sony BKDW-515 User Manual
![Sony](https://files.manualsbrain.com/attachments/7e61ba04cadfce70cb41a1a70ef1d62a30f0a5fe/common/fit/150/50/682a2570dc00831b079177f57c62a2915dd3423eb752334060fbcf750d89/brand_logo.png)
3-2
BKDW-515
ITEM
DATA
Description
No.
ITEM
No.
DATA
F13
TRACKING
0
off
Select whether the tracking control operation with search dial is enabled or not
CONTROL VIA
1
on
during DT head playback.
SEARCH DIAL
This item is prepared exclusively for DT adjustment and tracking adjustments.
After adjustment is completed, return to the factory setting ‘0 (off)’.
0:
After adjustment is completed, return to the factory setting ‘0 (off)’.
0:
Tracking control function is disabled during DT head playback.
1:
Tracking control function is enabled by rotating the search dial during PLAY
mode.
mode.
F15
ANALOG TAPE
0
disable
Enables LTC to be inserted in an analog tape (Betacam SP)
LTC INSERT
1
enable
0:
Inhibits insertion of LTC in an analog tape (factory setting)
1:
Enables LTC to be inserted in an analog tape
Note:
When set to “enable”, TC insert operation is executed even though the REC inhibit
tab of an analog tape used is set to REC INHIBIT.
When set to “enable”, TC insert operation is executed even though the REC inhibit
tab of an analog tape used is set to REC INHIBIT.
F16
DEVICE TYPE
0000
0
Determines the response data for the 9 pin remote command
MODIFY:0H
0001
1
DEVICE TYPE REQUEST (00h, 11h).
|
|
0000: Returns the original device type data of the DVW.
FFFF
FFFF
Except 0000: Returns the values numeric as it is.
The higher-order two digits are DATA-1.
The lower-order two digits are DATA-2.
Note:
The whole operations of the VTR including TTP is not influenced at all even if this
item is set to “0000” or “except 0000”.
For except DATA: 0000 (factory setting), the control from 9 pin is not guaranteed.
The higher-order two digits are DATA-1.
The lower-order two digits are DATA-2.
Note:
The whole operations of the VTR including TTP is not influenced at all even if this
item is set to “0000” or “except 0000”.
For except DATA: 0000 (factory setting), the control from 9 pin is not guaranteed.
3-1. ITEM-F Series