Sony HVR-1500 User Manual

Page of 111
95
Troubleshooting
  
A
ppe
ndix
Troubleshooting
If an alarm message appears on the monitor screen, or if 
the unit appears to be malfunctioning, please check the 
following before contacting your Sony dealer.
Tape problems
Time data problems
Symptom 
Cause
Remedy
Recording is not possible.
The cassette’s REC/SAVE 
switch is set to SAVE.
Set the REC/SAVE switch to REC, or use another cassette.
The unit’s tape transport 
control buttons (PLAY, F FWD, 
REW, etc.) do not work.
The remote control switch is 
set to other than LOCAL and 
the LOCAL ENABLE menu 
item is set to STOP & EJECT 
or ALL DISABLE.
Set the remote control switch to LOCAL, or change the setting 
of the LOCAL ENABLE menu item 
ENABLE.
No cassette is loaded. 
Insert a cassette.
The NO EDIT indicator on the 
LCD monitor lights up.
The audio recording mode 
selected on this unit does not 
coincides with that of the 
loaded tape.
• When your current purpose is editing, set the remote control 
switch to LOCAL and set the unit for the same audio 
recording mode as with the tape using the REC MODE menu 
item 
(see page 81), then set the switch to 9PIN or i.LINK.
• When your current purpose is recording, you can use the 
tape currently loaded in the unit.
The recording format of the 
currently loaded tape is HDV, 
DV or DVCPRO.
Replace the tape with one recorded in the DVCAM format.
The recording format selected 
on this unit is HDV or DV 
(SP).
Select the DVCAM format.
Symptom 
Cause
Remedy
Cannot freely set the initial 
time data value.
The TC MODE menu item is 
set to EXT REGEN.
Change the setting of the TC MODE menu item 
to INT PRESET.
CNT is selected as the time 
data type to be displayed (the 
CNT time data type indicator 
is lit).
Press the COUNTER SELECT button to make the TC or UB 
time data type indicator light up (the CNT value cannot be set 
freely).
The remote control switch is 
set to other than LOCAL and 
the LOCAL ENABLE menu 
item is set to STOP & EJECT 
or ALL DISABLE.
Set the remote control switch to LOCAL to turn the remote 
indicator off or change the setting of the LOCAL ENABLE 
menu item 
(see page 74) to ALL ENABLE.
The tape is running, but the 
time data is not shown in the 
time counter display.
The MENU button or TC 
PRESET button has been 
pressed.
Press the button once again to exit the menu control mode, 
timecode preset mode, or digital hours meter display mode.
(In either of the menu control mode and timecode preset mode, 
the time data is not shown in the time counter display.)
The UB time data type 
indicator is lit. 
Press the COUNTER SELECT button to make the CNT or TC 
time data type indicator lights up.